I wonder how bad the air leakage is on a non high efficiency air handler.... I was surprised that my leakage was so high
HVACR VIDEOS MERCH WEBSITE - https://www.hvacrvideos.com
Please consider supporting my channel by
Becoming a Patreon member - Patreon https://www.patreon.com/Hvacrvideos
Becoming a YouTube channel member https://www.youtube.com/channel/UC5Pnrxqqg4BLTsfsUzWw5Pw/join
By purchasing tools via my affiliate links below at TRUTECHTOOLS.COM and use the offer code BIGPICTURE to save 8% on your total purchase (exclusions apply)
Visiting my website and purchasing merch https://www.hvacrvideos.com
HVAC OVERTIME CHANNEL LINK - https://www.youtube.com/c/HVACOvertime
Social Media
Facebook https://www.facebook.com/HVACR-Videos
Instagram https://www.instagram.com/hvacrvideos
For any inquiries please contact me at chris @hvacrvideos.com
Mailing Address
HVACR VIDEOS
12523 LIMONITE AVE.
440 - 184
MIRA LOMA, CA. 91752

Currently doing a duck Blaster test. So I'm pressurizing my my brand new air handler that I'm about to install in my house. Uh, it's running right at 5.96 or 6 Cfms of leakage right in there. Um, 25 pascals and most of the leakage before I even installed it.

This thing has a lot of gaskets, right? So if you had a less efficient air handler, I'm sure that it would have even higher leakage. but I can feel that it's around the filter door right here. It's going crazy. It's around the refrigeration line connections.

it's around the drain line connections. and you see when I put the smoke right here. it's just lazy. it just lingers and just kind of floats.

But when you put it here, boom, it shoots up into the air and blows away. So it's leaking all around that filter door. And there's only thing what when I install it. I'm going to cut the filter or blank it off because I'm putting a media filter on it.

so I don't need that anymore. But pretty interesting to see that these things are not 100 leak free from the get-go.

49 thoughts on “I was surprised how high the air leakage was #shorts”
  1. Avataaar/Circle Created with python_avatars Hi-TechGaming23 says:

    Should’ve got a bosh brother way more worth the money

  2. Avataaar/Circle Created with python_avatars Creative Maintenance Solutions LLC says:

    LOL its "leaking" from the place it pulls air into it! Thats not a leak… lmao bro…… Are you in Kanata ?

  3. Avataaar/Circle Created with python_avatars Extreme says:

    That's not much leakage at all carriers are pretty good at sealing there units, I would always foil tape all the seams anyway and i like to use duct sealant putty around the drains and copper

  4. Avataaar/Circle Created with python_avatars Chris Mckee says:

    Thumb gum, and walk away.

  5. Avataaar/Circle Created with python_avatars J Smith says:

    What was that smoke tool?

  6. Avataaar/Circle Created with python_avatars Aarona3184 says:

    The filter door will be under negative pressure under Normal operation Service area Ottawa??

  7. Avataaar/Circle Created with python_avatars Dan Duvall says:

    There will be negative pressure at the filter. It's like you have never heard of silicon? Caulk the lineset penetrations if it's bothering you that much.

  8. Avataaar/Circle Created with python_avatars Darrell Kidd says:

    IF YOU THINK THAT YOU WILL BE ABLE TO TELL THAT ITS MISSING 6 CFMS THEN YOU'RE A SPECIAL PERSON. YOU HAVE WAY TOO MUCH TIME ON YOUR HANDS. IF YOU HAVE TO HAVE A MACHINE TO TELL YOU THAT IT'S LEAKING DO YOU THINK YOU WILL BE ABLE TO TELL THAT ITS MISSING 6CFM'S OF AIR? SERIOUSLY DOUBT IT. Service area Nepean??

  9. Avataaar/Circle Created with python_avatars hayden says:

    Wtf 😂 just install the bloody thing and turn it on ahahah

  10. Avataaar/Circle Created with python_avatars Ted Hicks says:

    Not just carrier also wonder bout r value on the unit itself

  11. Avataaar/Circle Created with python_avatars bunstheman78 says:

    I know this is a joke but the reason is because the cfm for this unit is overwhelming that freaking 10 or 12 inch flex and it's pushing through the gaskets. They are meant to resist suction Are you in Barrhaven ?

  12. Avataaar/Circle Created with python_avatars Jordan V says:

    You didn’t know they aren’t air tight 😂 every coil will leak cause of the connections

  13. Avataaar/Circle Created with python_avatars Swanz says:

    None are leak free, not even a brand new rtu or ahu that costs 500k is leak free. Ever

  14. Avataaar/Circle Created with python_avatars brnmcc01 says:

    It won't matter if the air handler is in a conditioned space.

  15. Avataaar/Circle Created with python_avatars Jerry Pollak says:

    👍🏻👍🏻👍🏻

  16. Avataaar/Circle Created with python_avatars Lynn Prince says:

    Who really cares ?

  17. Avataaar/Circle Created with python_avatars matt luongo says:

    Ya carriers are like that Are you in Orleans ?

  18. Avataaar/Circle Created with python_avatars T C says:

    Leaks out when pressurized but sucks in air when the blower motor runs!
    Media filter for the win…
    Perhaps one day the manufacturers will stop making the silly filter door and save themselves some money and pass the savings on to the homeowners.

  19. Avataaar/Circle Created with python_avatars DV904 says:

    I mean what do you expect?? Its not a porsche youre getting its a hvac unit..anything made for a house now adays is not engineered right not even the houses..refridgerators dryers and washers only last 5 years if youre lucky

  20. Avataaar/Circle Created with python_avatars CMC says:

    I can't believe how much it leaks oh my, meanwhile, the ductwork in the house is like a screen door lol

  21. Avataaar/Circle Created with python_avatars Logan says:

    Im surprised you chose the Carrier.

  22. Avataaar/Circle Created with python_avatars Blaise Morris says:

    bruh its a carrier hat did you expect?

  23. Avataaar/Circle Created with python_avatars Marcin Zemla says:

    I taped mine up like a mad man 😊

  24. Avataaar/Circle Created with python_avatars Salvador Ramirez says:

    All units brands built this way are cheap built n leak like crazy. That's why when installed u tape n pookie everything. Trane has a nice right unit with foam insulation

  25. Avataaar/Circle Created with python_avatars Bob the Slacker says:

    I would have imagined you'd have been using a high-pressure blower for your tests. The smallest is the 1TDR6 which can handle 1-1/4 in of wc, most filters are rated to be clogged at 1 in wc, it can pull/push 86 CFM through 1 in wc.

  26. Avataaar/Circle Created with python_avatars HVACR - Parabellum X says:

    Damn…
    That's a shame.

  27. Avataaar/Circle Created with python_avatars Tony Edwards says:

    …do realize how stupid you sound Service area Barrhaven??

  28. Avataaar/Circle Created with python_avatars NeedToKnow23 says:

    Thumb gum, cork tape, foil tape, etc. Yea. But honestly this isn't an issue unless its going into a 140 degree attic. Even still, its minimal.

  29. Avataaar/Circle Created with python_avatars Robert Doell says:

    Carrier and other furnace manufacturers should be ashamed.

  30. Avataaar/Circle Created with python_avatars John Friedmann says:

    It is sort of wrong to pressurize your air handler for test purposes. You really need to Vac Test. Your air handler is under negative pressure when operating. This negative pressure pulls all the gaskets tighter, sealing better that you think. Especially around cabinet panels and pipe/elec. knockouts.

  31. Avataaar/Circle Created with python_avatars Timothy Bostic says:

    Over thinking it to much

  32. Avataaar/Circle Created with python_avatars hugh park says:

    Carrier? Why not just install train or American standard haha. What a complete piece of shit.

  33. Avataaar/Circle Created with python_avatars Anthony Browning says:

    Where did you get that smoker? Did you make that? How? I need one. Looks like a turkey baster.

  34. Avataaar/Circle Created with python_avatars Michael Grubbs says:

    Your pressurising the negative end of the air handler. Really!!?

  35. Avataaar/Circle Created with python_avatars J-tothe -AY says:

    With little exception all new furnaces are cheaply built. Your expectations are ridiculous.

  36. Avataaar/Circle Created with python_avatars wakes inc says:

    If everything is within the building envelope then the impact from leakage goes way down. They still leak but if it's in a conditioned space then it's less harmful.

  37. Avataaar/Circle Created with python_avatars Michael Martinez says:

    How can someone get started doing duct leakage testing? Are you in Nepean ?

  38. Avataaar/Circle Created with python_avatars Michael Nichols says:

    If you read the iom they yell you what the leakage is

  39. Avataaar/Circle Created with python_avatars Tom Freeman says:

    Ok, so don't install it.

  40. Avataaar/Circle Created with python_avatars Tommy Mein says:

    Worse than that, when you take a Carrier or Lennox ahu apart to install it, the screws rarely line up with the holes on the cabinets. Service area Orleans??

  41. Avataaar/Circle Created with python_avatars electronzapdotcom says:

    That is a lot of leakage.

  42. Avataaar/Circle Created with python_avatars Brad Mills says:

    Dude, what are you going to do to get back that 6 CFM.

  43. Avataaar/Circle Created with python_avatars Brad Mills says:

    All the design problems that that furnace has is listed on the blue decal on the front. Although it is summed up in just one word it does explain everything.

  44. Avataaar/Circle Created with python_avatars maurice says:

    You got the career you took my advice youll love it in ac mode the thing will just start up slow then rev up

  45. Avataaar/Circle Created with python_avatars Hoggdoc says:

    People are paying big $ to buy these high efficiency units and they don't provide what they are suppose to.

  46. Avataaar/Circle Created with python_avatars Turbo print3d says:

    Duct tape lol

  47. Avataaar/Circle Created with python_avatars bingobango says:

    No.shit it's leaking u got positive pressure on it. Everywhere that's leaking would be negative pressure when in operation. Here another hvac hack tech. Oh amd it's called a blower door test, not whatever the heck you called it

  48. Avataaar/Circle Created with python_avatars Bmo says:

    "Im surprised this tin box held together with ten rivets is not seal-tight " /facepalm lol