Making progress on my system replacement.
HVACR VIDEOS NEW MERCH WEBSITE - https://www.hvacrvideos.com
Please consider supporting my channel by
Becoming a Patreon member - Patreon https://www.patreon.com/Hvacrvideos
Becoming a YouTube channel member https://www.youtube.com/channel/UC5Pnrxqqg4BLTsfsUzWw5Pw/join
By purchasing tools via my affiliate links below at TRUTECHTOOLS.COM and use the offer code BIGPICTURE to save 8% on your total purchase (exclusions apply)
Visiting my website and purchasing merch https://www.hvacrvideos.com
HVAC OVERTIME CHANNEL LINK - https://www.youtube.com/c/HVACOvertime
Social Media
Facebook https://www.facebook.com/HVACR-Videos...
Instagram https://www.instagram.com/hvacrvideos/
For any inquiries please contact me at chris @hvacrvideos.com
Mailing Address
HVACR VIDEOS
12523 LIMONITE AVE.
440 - 184
MIRA LOMA, CA. 91752

Doing some final stuff before we finally hook up my Carrier Infinity heat pump. So we went with a two ton. We're replacing my 4ton this last weekend. What I did was ran a whole new line set.

Still got a little bit more work to do in the Attic but we got Unistrut running the whole way over. Uh, we got 60 ft of pipe so far and then we got to make a couple connections here and there. We got a EMT for the thermostat wire ran all on Unistrut Um, it's just stubbed out here. it's capped on the ends.

We'll run newer stat wire and everything. Went ahead and remove the old disconnect switch that used to be right here. It was just being used as a junction box. put a 4x4 junction box EMT over into a new Euro style disconnect switch into a voltage monitor.

Uh, surge protector coming out of that into the condensing unit. Now this right here. This whip is temporary actually not even using the voltage monitor but just trying to do everything. Still got to go around and uh, seal these connections and everything.

so we're looking good. So far.

53 thoughts on “Making progress on my system replacment #shorts”
  1. Avataaar/Circle Created with python_avatars Jan Štěpán says:

    Going from 4t to 2t is possible due to vetter efficiency? Or was the 4t overkill to begin with? Btw such a clean install!

  2. Avataaar/Circle Created with python_avatars Devilsfan609 138 says:

    Talk about a bunch of unnecessary bull shit

  3. Avataaar/Circle Created with python_avatars Gerardo Rivera says:

    Nice and clean job and it better be or the wife kick your ass 😂

  4. Avataaar/Circle Created with python_avatars Erik Kovacs says:

    Why did you run a new line set? Don't get me wrong no one uses unistrut on residential installations but the old line set is ran in the walls.

  5. Avataaar/Circle Created with python_avatars Cloudy The Samoyed says:

    Wow dude! That’s a nice set up! Just a question? How much you paying your employees out there in California? Service area Nepean??

  6. Avataaar/Circle Created with python_avatars Peter Mcadam says:

    Carrier infinity is garbage ! This video is sponsor by Sporlan

  7. Avataaar/Circle Created with python_avatars Tim Castilo says:

    Incredible

  8. Avataaar/Circle Created with python_avatars JWP says:

    B e a u t i f u l😮

  9. Avataaar/Circle Created with python_avatars StormWolv ` says:

    replace the metal conduit with rubber it will mess with communication over time and cause boards to fail. and I'm so sorry you're going with carrier. it's the worst brand Are you in Ottawa ?

  10. Avataaar/Circle Created with python_avatars DHARMVEER DHARMVEER says:

    ❤❤❤❤❤❤❤ Service area Barrhaven??

  11. Avataaar/Circle Created with python_avatars Lynn Prince says:

    This is why you hire a pro, against code to wrap liquid line dummy…plus you can only size a unit when using a manual J calculation.

  12. Avataaar/Circle Created with python_avatars MK says:

    How do you make your Lineset insulation look so good at the corners

  13. Avataaar/Circle Created with python_avatars John wa says:

    Why did you decide to replace a two ton with a four ton

  14. Avataaar/Circle Created with python_avatars Michael Shanahan says:

    Tell me you do commercial without telling me you do commercial 😂🤣😂

  15. Avataaar/Circle Created with python_avatars burningdust says:

    Brings a smile to my face. It’s a beautiful install. And yet you say you’re not an installer.
    All the little things like running the thermostat line in emt will add to the reliability and longevity of the system. Trouble free operation for years when things are done right!

  16. Avataaar/Circle Created with python_avatars Kevin Thomas says:

    Do you have a link for that disconnect and surge protector?

  17. Avataaar/Circle Created with python_avatars Ruben P says:

    With as much as some places are charging for change outs you would expect this level of work.

  18. Avataaar/Circle Created with python_avatars Copper Cowboy 🤠 333 says:

    Amazing 👏 craftsmanship 💯

  19. Avataaar/Circle Created with python_avatars Robby Ketcherside says:

    Great equipment, I love the carrier green speed 25vna4. I work for level 9 hvac and we sell carrier and lennox high efficiency systems and in my opinion carrier has far less issues.
    I specialize in geothermal units if the investment can be made thats the best unit around in my Area. Check out the climatemaster Qe trillogy units they are inverter driven Geos and do 100% of your hotwater heating 45 seer plus easy and get a 30% federal tax credit.

  20. Avataaar/Circle Created with python_avatars PigeonFuff says:

    Beautiful work! Are you in Nepean ?

  21. Avataaar/Circle Created with python_avatars AUSPetrol says:

    Just got my CT-XL today – its everything you made it out to be, cant wait to kit it out 👏 thanks for the hot tip mate!

  22. Avataaar/Circle Created with python_avatars Ulysses Rodriguez says:

    You should do more installing. You do really nice work 🤔👍

  23. Avataaar/Circle Created with python_avatars boywhohadatiger says:

    4 ton to a 2 ton wow

  24. Avataaar/Circle Created with python_avatars Joseph Tran-Day says:

    I just had an orgasm looking at them lineset and electrical pipes 😂

  25. Avataaar/Circle Created with python_avatars HVAC with Greg says:

    looking forward to the video Service area Ottawa??

  26. Avataaar/Circle Created with python_avatars Rich Woodcock says:

    How are you going from a 4 ton to a 2 ton unit? Was the old one oversized that much???

  27. Avataaar/Circle Created with python_avatars Kevin says:

    This is really nice for residential… but should be the standard imo

  28. Avataaar/Circle Created with python_avatars HVAC Slayer says:

    This is how I have the central ran at my house. Uni holding the line set but I wrapped mine with white E flex guard. Just installed mini for my master room that was an add on, added shallow uni inside Rectorseal line set cover to hold line set better.

  29. Avataaar/Circle Created with python_avatars P R Doohan says:

    Awesome, love the position of the lineset drop. It will be nicely hidden from view while enjoying the yard 👌

  30. Avataaar/Circle Created with python_avatars Richard Harmon says:

    Nice work

  31. Avataaar/Circle Created with python_avatars hackfreehvac says:

    Nice.
    My downstairs unit is still a shifty Goodman recipe heat pump.
    The AHU is in the 2nd floor attic with duct drops thru chases.
    I'm tempted to install a Carrier VRF or mini VRF with ceiling cassettes downstairs.
    Then I'd get larger closet space when I removed the vertical duct chases.

  32. Avataaar/Circle Created with python_avatars Taylor Quin says:

    Xtra af

  33. Avataaar/Circle Created with python_avatars DesertFox says:

    Very nice 👍🏻

  34. Avataaar/Circle Created with python_avatars TheGoodGuy says:

    Looking super clean.

  35. Avataaar/Circle Created with python_avatars Ivory Johnson says:

    Looks good

  36. Avataaar/Circle Created with python_avatars Kelley Hagan says:

    That's first class. Excellent work.

  37. Avataaar/Circle Created with python_avatars Ask Me says:

    Better get that extended warranty on that infinity 🤣🤣🤣 i see them blow condenser and evap fan motors, and control boards all the time and they aren't 2-300 parts. 1000+ for those variable speed and control boards. Also have seen problems with the loader unloader scrolls. But that looks like it's the variable speed compressor. Hope its not an LG 😬😬😬

  38. Avataaar/Circle Created with python_avatars Semi says:

    Loooking awesome 🎉

  39. Avataaar/Circle Created with python_avatars mark smith says:

    Home improvements are good for years to come Are you in Kanata ?

  40. Avataaar/Circle Created with python_avatars Ben Berding says:

    The CLEANEST install!! I’m dying, it’s amazing. Truly my dream install. 🔥🔥🔥 Are you in Barrhaven ?

  41. Avataaar/Circle Created with python_avatars Brandon Graser says:

    Recommendation: I would highly recommend considering putting radiant barrier insulation around the line sets. However, now that I think about it . Maybe not since you have a heat pump you're going to need that radiant heat in the winter to help out with the heat pump. Even though inverter heat pumps are awesome. The heat like no other heat pump.
    I don't know it's something to think about.
    I just recommended it to shield the line. Sets/ insulation from radiant heat and UV.

  42. Avataaar/Circle Created with python_avatars James Last Name says:

    Love it when commercial grade quality is done on residential. So clean!

  43. Avataaar/Circle Created with python_avatars harold andres a. says:

    Soy un admirador de tu trabajo. Un abrazo desde Colombia parcero! Service area Orleans??

  44. Avataaar/Circle Created with python_avatars Antonio Fabro says:

    Nice looking good !! Professional

  45. Avataaar/Circle Created with python_avatars Bort Scrumbo says:

    EMT for the thermostat wire!! damn, fancy

  46. Avataaar/Circle Created with python_avatars Fleur de lune says:

  47. Avataaar/Circle Created with python_avatars TheNukem13 says:

    You should consider Bronco Saddles rather than hydrozorbs for your horizontal line set runs in the attic. Through they don’t mech fasten the line set to the strut, the saddles snap into the strut groove and they don’t need to disturb the lineset insulation. Will save you some joint glue and taping in the 120 degree plus attic.
    Happy hunting from Massachusetts Service area Kanata??

  48. Avataaar/Circle Created with python_avatars stonersgarden says:

    I've been an hvac tech since 91 and questioning why are you replacing a 4ton with a two ton unit. Just because it's a heatpump doesn't mean you can get away with half the needed tonnage. Otherwise, very nice clean installation

  49. Avataaar/Circle Created with python_avatars Giggledoodle doodle says:

    Good shit

  50. Avataaar/Circle Created with python_avatars thehappyTexan says:

    What do you think about using a euro style 3 pole switch on a rtu? Or would you stick with the old lever box?

  51. Avataaar/Circle Created with python_avatars Dead Men's Tots says:

    What kind of surge protector are you using?

  52. Avataaar/Circle Created with python_avatars Jesus Tapia says:

    It finally looks like my wish of Chris finishing the project before my birthday might actually happen.

  53. Avataaar/Circle Created with python_avatars Zac Cody says:

    Line set looks nice. I'm a big fan of the individual holes. Makes air sealing much easier and effective

Leave a Reply

Your email address will not be published. Required fields are marked *

This site uses Akismet to reduce spam. Learn how your comment data is processed.