In this video, Joshua Griffin answers a question on whether gauges should be connected on every HVAC service call. This is a clip from our live show that we have every Tuesday night at 8:30 PM Eastern standard time. Joshua had a special guest named Larry Mason, who is an expert in home renovations and the two discuss the ins and outs of whether gauges should be connected on every single service call. They also discuss the good and bad sales tactics used by many HVAC contractors.
For more information on New HVAC Guide, visit https://www.newhvacguide.com/overview
*Need Financing for your HVAC? Visit https://www.newhvacguide.com/financing
*Own a Service Biz and want to grow? Visit https://www.newhvacguide.com/mastermindgroup
*Our favorite products?
Favorite Thermostat click here: https://amzn.to/3wt3Vwh
Favorite Air Cleaner here: https://www.daikinairpurifier.com/?affiliate_code=ThMSZHEks4&referring_service=link
Favorite Air Filter here: https://amzn.to/3vpVbWl
Air Tester/Monitor here: https://amzn.to/3oJ3LvD
Dehumidifier here: https://amzn.to/3Q4woPp
Humidifier here: https://amzn.to/3ilZ9vq
Smart Vent here: https://amzn.to/3JDfGDX
HVAC Soft Start: https://amzn.to/3kMXlwT
HVAC Guide for Homeowners is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program to provide a means for sites to earn advertising fees by advertising and linking to amazon.com. Amazon offers a small commission on products sold through their affiliate links. Each of your purchases via our Amazon affiliation links supports our cause at no additional cost to you.
Griffin Air and Joshua Griffin have partnered with Daikin on multiple projects. FTC requires disclosure of these relationships due to the compensation received.
#hvac #gauges #airconditioner

8 thoughts on “Should gauges be connected on every hvac service call? answer here!”
  1. Avataaar/Circle Created with python_avatars @bradberry9312 says:

    I stopped hooking my gauges up on maintenance calls once I discovered the feature on the Fieldpiece blue tooth psychrometers that can measure BTU output. If theres no customer complaint about anything and my condenser coil is clean, static pressure is good, my btu output is good on my fieldpiece probes, line temps are good, my delta T is good, and my compressor amp draw is good there's no need to check pressures. If any of those readings are off then I'll hook up and see what's going on my with pressures.

    If you put gauges on a system twice a year for routine maintenance and don't purge and equalize your hoses (which 90% of techs don't do) it's going to be low on refrigerant after a few years and you're going to be telling the customer they have a leak when in reality there is no leak and the cause of low refrigerant is the fault of the company that's been doing the maintenance and taking a little bit of refrigerant out every time they hook up. Or worse, you might contaminate the refrigerant and cause a problem that could have otherwise been avoided. Thats my opinion anyway.

  2. Avataaar/Circle Created with python_avatars @heavydiesel says:

    Here we are not supposed to routinely use gauges, only if you suspect there is a fault or to perform a repair etc.

  3. Avataaar/Circle Created with python_avatars @chesstime356 says:

    If your on cooling check up on 7 years old system and it’s existing customer still do you checking pressures or not?

  4. Avataaar/Circle Created with python_avatars @CommercialGasEngineerVideos says:

    I could do with some guages 😢

  5. Avataaar/Circle Created with python_avatars @RapidRepair says:

    Great information Josh 🛠️🛠️

  6. Avataaar/Circle Created with python_avatars @ohiopat8517 says:

    If it wasn't leaking the valve core may start leaking if you mess with it. I always felt the temperature of the lines and didn't use gauges unless unless needed.

  7. Avataaar/Circle Created with python_avatars @Adam-ul2px says:

    I do not attach gauges unless I believe there might be an issue with the refrigeration circuit. Besides the small loss of refrigerant, my main concern is contaminating a system with air or grime in my gauges. I will measure the temp split, amp the compressor and measure my lineset temps and compare to what I would expect it to be, seems to be the least invasive way, imo

  8. Avataaar/Circle Created with python_avatars @EverythingHVACR says:

    Non invasive diagnostics works great, I'm not connecting Guages to everything Service area Nepean??

Leave a Reply

Your email address will not be published. Required fields are marked *

This site uses Akismet to reduce spam. Learn how your comment data is processed.